summaryrefslogtreecommitdiff
authorspiralman <spiralman>2002-08-12 21:27:47 (UTC)
committer spiralman <spiralman>2002-08-12 21:27:47 (UTC)
commit598c77cf0a0f934b0835498ba2ac9710cf60d8ca (patch) (unidiff)
treeb981a244863697df17dc828d4ad7d7265508eb08
parent6a83ebf59b68cd8b87f03ef15f07d39748726408 (diff)
downloadopie-598c77cf0a0f934b0835498ba2ac9710cf60d8ca.zip
opie-598c77cf0a0f934b0835498ba2ac9710cf60d8ca.tar.gz
opie-598c77cf0a0f934b0835498ba2ac9710cf60d8ca.tar.bz2
added info on beaming contacts, tasks, and appointments, plus files from the documents tab.
Diffstat (more/less context) (ignore whitespace changes)
-rw-r--r--docs/usermanual/calendar.sgm11
-rw-r--r--docs/usermanual/contacts.sgm11
-rw-r--r--docs/usermanual/irda.sgm13
-rw-r--r--docs/usermanual/todo.sgm11
4 files changed, 42 insertions, 4 deletions
diff --git a/docs/usermanual/calendar.sgm b/docs/usermanual/calendar.sgm
index 3257ae0..99a810c 100644
--- a/docs/usermanual/calendar.sgm
+++ b/docs/usermanual/calendar.sgm
@@ -189,2 +189,11 @@ Click "Find" to find the next appointment that matches your criteria.
189</section> 189</section>
190</chapter> \ No newline at end of file 190
191<section><title>Beaming Appointments</title>
192<para>
193To beam an appointment to another device using the IrDA and OBEX protocols, you must first install the IrDA
194Applet and enable IrDA with it (see <xref linkend=irda>). Then select the appointment that you would like to
195send in the Day View, and select Beam from the menu that appears. Opie will then send the appointment to any
196waiting device.
197</para>
198</section>
199</chapter>
diff --git a/docs/usermanual/contacts.sgm b/docs/usermanual/contacts.sgm
index a3ad34a..8ba7674 100644
--- a/docs/usermanual/contacts.sgm
+++ b/docs/usermanual/contacts.sgm
@@ -91,2 +91,11 @@ times to get to "B" and 2 more times to get back to all letters. 2+2=4).
91 91
92<section><title>Beaming Contacts</title>
93<para>
94To beam a contact to another device, you must first have the IrDA Applet installed, and you must enable IrDA in it.
95(see <xref linkend=irda>). Once this is done, you can select the contact you would like to beam, and press the
96beam icon in the toolbar, or select Contact&arrow;Beam Entry. Opie will then send the contact using the IrDA and
97OBEX protocols to any waiting device.
98</para>
99</section>
100
92<section><title>Personal Details</title> 101<section><title>Personal Details</title>
@@ -98,2 +107,2 @@ display who the device belongs to, as well as other apps.
98</section> 107</section>
99</chapter> \ No newline at end of file 108</chapter>
diff --git a/docs/usermanual/irda.sgm b/docs/usermanual/irda.sgm
index 2ca48c6..a2f084c 100644
--- a/docs/usermanual/irda.sgm
+++ b/docs/usermanual/irda.sgm
@@ -1,2 +1,2 @@
1<chapter><title>IrDA Applet</title> 1<chapter id=irda><title>IrDA Applet</title>
2<para> 2<para>
@@ -27,2 +27,13 @@ IrDA Applet's menu so that you are not wasting system resources.
27</section> 27</section>
28<section><title>Beaming Files</title>
29<para>
30Several applications support beaming files in a format specific to that application (specifically, Contacts, Calendar,
31and Todo). However, sometimes you may need to simply send a file to another device via IrDA, regardless of the
32file type. To do this, you can use either AdvancedFM (yet to be documented), or you can do this from the
33Documents tab. To beam a file from the Documents tab, you must first add that file to the Documents tab if you
34havent already (see <xref linkend="adddoc">). Then, go to the Documents tab and press and hold on the icon for
35the file you want to send. A dialog should appear, with a button in the bottom right labeled "Beam". Press this
36button, and Opie will beam the file to any waiting devices.
37</para>
38</section>
28<section><title>Stoping IrDA</title> 39<section><title>Stoping IrDA</title>
diff --git a/docs/usermanual/todo.sgm b/docs/usermanual/todo.sgm
index f7c5f11..18138d9 100644
--- a/docs/usermanual/todo.sgm
+++ b/docs/usermanual/todo.sgm
@@ -85,2 +85,11 @@ again.
85</section> 85</section>
86</chapter> \ No newline at end of file 86
87<section><title>Beaming Tasks</title>
88<para>
89To beam a task to another device using the IrDA and OBEX protocols, you must first install the IrDA
90Applet and enable IrDA with it (see <xref linkend=irda>). Then select the task that you would like to and select
91press the Beam icon in the toolbar, or select Data&arrow;Beam. Opie will then send the task to any waiting
92device.
93</para>
94</section>
95</chapter>